True-rms Digital Multimeter
Detailed Specifications
31
MIN MAX Recording
Nominal Response Accuracy
100 ms to 80 %
(dc functions)
Specified accuracy ±12 counts for changes >200 ms in duration
120 ms to 80 %
(ac functions)
Specified accuracy ±40 counts for changes >350 ms and inputs >25 % of range
250 μs (peak)
[1]
Specified accuracy ±200 counts for changes >250 μs in duration
(add ±100 counts for readings over 6000 counts)
(add ±100 counts for readings in Low Pass mode)
[1] For 6 V range: 1 ms