Table
2-8.
IEEE-488
Commands
(cont)
Rej
ected
Entry
IR
none none Interrogates the
rejected en-
try
error codes. The Generator
responds
with three octal
fields: "AAAAAA, BBBB88,
CCCCCC".
See Table
2-6
for
a
list of
rejected entry
error codes.
Serial
Number
IS none none
Interrogates the instrument
serial number.
Self Test
IT none none Interrogates
the results
of
the self tests. The
Generator
responds with the
self-test
results. See paragra
graph 4D-20
for self-test
codes.
UN CAL lU
none none Interrogates the
uncali-
brated
output
error
codes.
The Generator
responds with
three
octal fields:
"AAAAAA,
BBBBBB, CCCCCC”.
See Table
2-5
for a
list of
uncal
error codes.
Software
Version
IV
none none
Interrogate
the software
ver-
sion.
The Generator
responds
with the status
message;
"Vxx.x"
where x's
are decimal
digits representing
the
current
software revision
level.
Compensation
Memory
Status
11
none none
Interrogates
the compensation
memory status.
The Generator
Responds
with three
fields:
"AAAAAA,
BBBBBB, CCCCCC". See
Table 4D-7
for
a
list of
status
codes.
MEMORY ENTRY
Recall RC int
none
Recall the
front panel
setup
stored
at the
memory location
specified by int.
Store
ST int
none Store
the current front
panel
setup at
the memory
location
specified by
int.
Sequence SQ
none none
Sequence
(recall) to
the next
higher
memory location.
MODULATION
ENTRY
|
Program AM AM
float PC
Program AM
depth in
percent,
|
External AM AE 0/1
none
Di
sable/enable external
AM
Internal AH A1 0/1
none
Disable/enable
internal AM