DTX Series CableAnalyzer
Technical Reference Handbook
4-6
Figure 4-4. Examples of AC Wire Map Results for Complex Faults
amd43.bmp
amd44.bmp
The tester detected one or more wire map faults on pairs
1,2 and 3,6 about 4 ft from the tester. The distance to
faults may not be given for some types of complex faults.
The tester detected multiple, complex faults on the
cabling.