Certifying Coaxial Cabling
Coaxial Autotest Results
5-9
5
Coaxial Autotest Results
Figure 5-5 describes the Autotest Summary screen, which
lists the tests that apply to coaxial cabling.
Note
The Autotest runs some or all of the tests shown in
Figure 5-5, depending on the selected test limit.
Figure 5-5. Autotest Results for Coaxial Cabling
amd141f.eps
A
PASS: All parameters are within limits.
FAIL: One or more parameters exceed the limit.
B
E: The test passed.
i: The parameter was measured, but has no PASS/FAIL limit in the
selected test limit.
X: The test failed.
C
The worst margin found for the test.