Custom Test Settings
Creating a Custom Limit for Loss/Length Tests
12-5
12
Creating a Custom Limit for Loss/Length
Tests
You can create up to nine custom fiber limits for loss/length
tests.
A custom fiber limit for loss/length tests includes the
following settings:
Custom limit name
Baseline limit for default values
Maximum fiber length
Maximum loss at the wavelengths required by the
baseline limit.
To create a custom fiber limit:
1
Turn the rotary switch to SETUP; then select Fiber Loss.
2
Select Test Limit, press J More; then select Custom.
3
Press J Create.
4
On the Custom screen, select Name; then use the text
editing screen to enter a name for your custom fiber
limit. Press
N when you are done.
5
On the Custom screen, select Use Default Values From,
select a limit group; then select a fiber limit as a
baseline for your custom limit.
6
The Custom screen shows other settings on multiple
tabs for the fiber test limit. Use AD and
H to select settings to change. Use BC to move
among the tabs.
See page 8-14 for details on loss/length test settings.
7
From the Custom screen, press N when you are done
creating the limit.
The tester saves the custom limit in the Custom list,
with asterisks (*) before and after the name.