Custom Test Settings
Creating Custom Limits for OTDR Tests
12-7
12
Creating Custom Limits for OTDR Tests
You can create up to nine custom limits for OTDR tests. Each
limit can include multiple fiber types.
Table 12-1 describes the settings used in custom OTDR limits.
To create a custom fiber limit for OTDR tests:
1
Turn the rotary switch to SETUP; then select Fiber OTDR.
2
Select Test Limit; then select Custom. If Custom is not in
the list, press
J More to see more test limits.
3
Press J Create to create a new limit.
4
On the Custom Limit screen, select Name; then use the
text editing screen to enter a name for your custom
OTDR limit. Press
N when you are done.
5
On the Custom Limit screen, select Use Default Values
From, select a limit group; then select a fiber limit as a
baseline for your custom limit.
6
On the Custom Limit screen, press J Select Fiber;
then do one of the following:
Highlight a fiber type for the custom limit.
To add a fiber to the list, press K Add Fiber,
select a fiber group, select a fiber type; then
highlight the added fiber on the Custom screen.
7
With the desired fiber type highlighted on the Custom
Limit screen, press
J Edit Limit.
8
The Custom Limit screen shows other settings on
multiple tabs for the OTDR test limit. Use AD
and
H to select settings to change. Use BC to move
among the tabs.
See Table 12-1 for details on custom OTDR test settings.
9
From the Custom Limit screen, press N when you are
done creating the limit.
The tester saves the custom limit in the Custom list, with
asterisks (*) before and after the name.