7-34
Using the Measurement Cursor
You can use the cursor on the OTDR trace to measure
distances and losses along the cabling.
To make measurements with the cursor:
1
Press K Change to Cursor if necessary to set the
arrow keys to cursor mode.
2
Move the cursor to a starting point for a measurement.
Use BC to move the cursor left or right or
AD to move the cursor to the previous or
next event.
3
Press Hto mark the starting point for the
measurement.
4
Use BCAD to move the cursor to the
ending point for the measurement.
The following readouts appear on the screen:
Δ m or Δ ft: The distance between the cursor and
the mark.
Δ dB: The difference in the power levels (in
decibels) between the cursor and the mark.
5
To clear the mark press H.