Maintenance and Specifications
Specifications
14-15
14
Propagation Delay
Delay Skew
DC Loop Resistance Test
Parameter
Twisted pair cabling
Without Remote With Remote
Range 4000 ns 750 ns
Resolution 1 ns 1 ns
Accuracy ± (2 ns + 2 %);
0 ns to 750 ns
± (2 ns + 4 %);
750 ns to 4000 ns
± (2 ns + 2 %)
Parameter Twisted Pair Cabling
Range 0 ns to 100 ns
Resolution 1 ns
Accuracy ± 10 ns
Parameter Twisted pair cabling
Range 0 Ω to 530 Ω
Resolution 0.1 Ω
Accuracy ± (1 Ω + 1 %)
Overload
Recovery Time
Less than 10 minutes to rated
accuracy following an overvoltage.
Referencing is required after
repeated or prolonged overvoltage.