DTX Series CableAnalyzer
Technical Reference Handbook
14-20
amd110f.eps
Figure 14-5. Baseline Insertion Loss Measurement Accuracy
0
0.5
1
1.5
2
2.5
0 100 200 300 400 500 600
Frequency in MHz
Accuracy in dB
Network Analyzer Accuracy
Level IV Accuracy
Best Case DTX Accuracy
Worst Case DTX Accuracy
WorseBetter

Table of Contents