EasyManua.ls Logo

Fluke DTX-1800 - Test the Cord in both Directions

Fluke DTX-1800
398 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DTX Series CableAnalyzer
Technical Reference Handbook
A-6
4. Test the Cord in Both Directions
4-1
Disconnect the test reference cord from the INPUT port
of the tester (Figure A-4,
A
).
4-2
Connect the cord you want test (Figure A-4,
B
).
4-3
Turn the rotary switch to AUTOTEST, then press P.
This test measures the loss of connector shown in
Figure A-4.
4-4
When the first part of the test is completed, connect
the cord in the opposite direction (Figure A-4,
C
).
4-5
Press KOK. This test measures the loss of connector
shown in Figure A-4.
5. Read the Loss Measurements
Compare the loss measurement for each direction to these
limits:
Multimode test reference cord: 0.10 dB or less
Singlemode test reference cord: 0.20 dB or less
If the connectors show no contamination or damage, but
the loss is
higher than these limits, the cord does not comply
with ISO/IEC 14763-3. Do not use the cord as a test
reference cord.