17
Applications
67 500 Belden 88760 2 wire shielded 18
AWG, Red-Black
68 500 Belden 88760 2 wire shielded 18
AW
G, Red/Black-Shield
64 500 Carol C1156 RG-174/U
57 500 BICC General, E22025, Red-Black
73 1000 Channel Master Polyclad Model
9354 300 Ohm Foam A
ntenna
Wire
71 2000 Triangle Wire and Cable, type
NM-B 12/2 W/G, Black-Ground
67 2000 Triangle Wire and Cable, type
NM-B 12/2W/G, Black-Whit
e
T
able 2. Values and Maximum Length for Specifically
Identified Cables (con
tinued)
VOP
Maximum
Length (Feet) Cable

Other manuals for Fluke TS 90