Chapter 8: Inspect Fiber Endfaces
Settings for FiberInspector Tests
221
3 On the TEST SETUP screen, tap the panels to change settings
for the test. See Table 10.
4 On the TEST SETUP screen, tap SAVE when your test setup is
completed.
5 On the CHANGE TEST screen, make sure the button next to
the test is selected, then tap USE SELECTED.
Table 10. Settings for FiberInspector Tests
Setting Description
Module Select a CertiFiber Pro or OptiFiber Pro module or
FI-7000.
Test Type Select FiberInspector.
Test Limit To give images a PASS or FAIL result manually, select
Manual. Or, select a limit to compare scratches and
defects to specific criteria for size and location.
To see a different group of limits, tap MORE, then tap
the name of a group. To make a custom limit, tap
Custom in the Limit Groups list. See Chapter 19.