FCS-21200-12 2012 Focus Electric Emergency Response Guide Page 10 of 23
NOTE : To gain access to the upper battery high-voltage service disconnect, the rear 60%
seat backrest must be lowered.
Locate the seat backrest release lever at the top of the seatback.
Push the release lever at the top of the seatback.
HIGH-VOLTAGE SERVICE DISCONNECTS
Remove the cover to access the upper battery service disconnect.
WARNING: ELECTRIC VEHICLES DAMAGED BY A CRASH MAY HAVE COMPROMISED
HIGH VOLTAGE SAFETY SYSTEMS AND PRESENT A POTENTIAL HIGH VOLTAGE
ELECTRICAL SHOCK HAZARD. EXERCISE CAUTION AND WEAR APPROPRIATE
PERSONAL PROTECTIVE EQUIPMENT (PPE) SAFETY GEAR, INCLUDING
HIGH VOLTAGE SAFETY GLOVES AND BOOTS. REMOVE ALL METALLIC JEWELRY,
INCLUDING WATCHES AND RINGS. ISOLATE THE HIGH VOLTAGE SYSTEM AS
DIRECTED BY THE FORD EMERGENCY RESPONSE GUIDE FOR THE VEHICLE.
FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN SERIOUS PERSONAL
INJURY OR DEATH.