Ignition Switch C250
Message Center Switch C253
Parking Brake Switch C306
Fuel Pump Sender C433, C434 Remote Fuel Sender
24 608 (BK/YE) air bag warning indicator control
circuit
0 volts, less than 5 ohms between the instrument cluster and the RCM. Greater than 10,000 ohms between the instrument
cluster and ground.
25 1266 (RD/YE) B+ voltage feed, hot in the
START/RUN positions
Greater than 10 volts with the ignition switch in the START/RUN position. Less than 5 ohms between the instrument cluster
and the SJB. Greater than 10,000 ohms between the instrument cluster and ground.
26 489 (PK/BK) B+ voltage feed, hot in the
START/RUN positions
Greater than 10 volts with the ignition switch in the START/RUN position. Less than 5 ohms between the instrument cluster
and the SJB. Greater than 10,000 ohms between the instrument cluster and ground.
Pin Number(s) Circuit Designation/Description Normal Condition/Measurement
5 1414 (LG/VT) key-in-ignition switch input 0 volts, less than 5 ohms between the ignition switch and the instrument cluster.
Pin Number
(s) Circuit Designation/Description Normal Condition/Measurement
2 1411 (GY/OG) message center switch
input
0 volts, less than 5 ohms between the message center switch and the instrument cluster. Greater than 10,000 ohms between the
message center switch and ground.
3 1410 (TN/OG) message center switch
return
0 volts, less than 5 ohms between the message center switch and the instrument cluster.
Pin Number
(s) Circuit Designation/Description Normal Condition/Measurement
1 1309 (RD/YE) brake warning indicator, parking
brake input circuit
Less than 5 ohms between the parking brake switch and the smart junction box (SJB). Greater than 10,000 ohms
between the parking brake switch and ground.
2 1205 (BK) brake switch ground 0 volts, less than 5 ohms between the parking brake switch and ground.
Pin Number
(s) Circuit Designation/Description Normal Condition/Measurement
2 1357 (LB/YE) fuel level return signal Less than 5 ohms between the fuel pump sender and the smart junction box (SJB). Greater than 10,000 ohms between the fuel
pump sender and ground with the instrument cluster disconnected.
4 (C434) 29 (YE/WH) fuel level variable input
signal
0 volts, less than 5 ohms between the fuel pump sender and the SJB.
2005 Mustang Workshop Manual
http://www.fordtechservice.dealerconnection.com/pubs/content/