Setup 69
3. Confirm your entry with .
5.11 Communication
5.11.1 Printer
Current animal lists can be generated via the automatic feeder’s printer function.
Serial: Select this option if you have connected a printer to the automatic feeder via the se-
rial interface.
CAN: Select this option if the printing data is to be sent via the CAN bus. In this case, a PC
program will play the counterpart.
5.11.2 Network configuration
Here you can configure all parameters of the network.
(M) MAC address: Here you can see the MAC address of your network. Your processor
card is uniquely identified via its MAC address. This address cannot be changed.
M-ECN: Here the check sum of the MAC address is displayed.
(IP) IP address: Here you can see the IP address of your processor card and if necessary
change it.
(SN) Subnet mask: Here you can see the subnet mask of your network and if necessary
change it.
(GW) Gateway: Here you can see the IP address of your gateway and if necessary change
it.
IP assignment: If you set the value here to DHCP, your processor card will try to get its IP
address from a DHCP server in your network. If you select static here, you will have to set
the IP address of your processor card yourself, in consultation with your IT specialist.
Note: If after 10 seconds no IP address has been set by the DHCP server, the IP address
169.254.2.1 will be used automatically.
Accept?: Press here . The data will be saved.
5.11.3 Cloud
Here you can change the values for the CalfCloud and the automatic feeder's Internet connec-
tion to the cloud.
1. In start?, press . You then create the connection between the cloud and the automatic
feeder.
2. You will see the message You hereby accept the data protection provisions listed on
www.calf-cloud.com!.
3. Press . The error menu last error will appear.
none. There are no errors present.
no eth. cable. No Ethernet cable is plugged in.
no Internet. There is no Internet connection available.
connect.error. There is a connection error to the server.