Install the outer rails on a rack
1. Ensure that the right and left rails are correctly identified.
Bracket
Front
Bracket
Rear
2. Press the front of the outer rail into three available screw holes on the front of the
rack until you hear a click.
3. Ensure that the rail is level, then slide the rear of the rail over three holes on the back
of the rack until you hear a click.
No screws are required to secure the rail to the rack.
4. Repeat steps 2 - 3 for the remaining outer rail.
Install the device into the rack
1. Ensure that there is enough room around the unit to allow for sufficient air flow.
2. Ensure that the inner rails are properly connected to the device, and the that the
outer rails are securely attached to the rack.
3. Align the inner rails with the outer rails and slide the device onto the rails until the
locking tabs click into the locked position.
Ensure that even pressure is applied to both sides of the device while doing this.
4. Simultaneously push the locking tabs on both sides while pushing the device all the
way into the rack.
5. For additional security, secure the handles to the front of the rack with the two
provided rack mount screws.
To remove the device from the rack, pull it out as far as it will go, then push the
locking tabs on both sides and slide the device out.
After the device is installed in the rack, plug the provided power cable into the rear of
the unit, and then into a grounded electrical outlet or separate power source, such as an
uninterruptible power supplies (UPS) or a power distribution units (PDU).
To install the unit on a at surface
1. Ensure that the surface onto which the FortiSandbox unit to be installed is clean,
level, and stable, and that there is at least 1.5in (3.8cm) of clearance on all sides to
allow for adequate airflow.
2. Attach the provided rubber feet to the bottom of the unit.
3. Place the unit in the designated location.
4. Verify that the spacing around the unit conforms to requirements and that the unit is
level.
1.5in
1.5in
5. Plug the provided power cable into the rear of the unit, and then into a grounded
electrical outlet or separate power source, such as an uninterruptible power supplies
(UPS) or a power distribution units (PDU).