Fortinet Technologies Inc. Page 59 FortiVoice Enterprise Phone System 4.0.0 Administration Guide
Monitor Displays the time at which the secondary unit’s HA daemon
will check to make sure that the primary unit is operating
correctly, and, if monitoring has detected a failure, the number
of times that a failure has occurred.
Monitoring occurs through the heartbeat link between the
primary and secondary units. If the heartbeat link becomes
disconnected, the next time the secondary unit checks for the
primary unit, the primary unit will not respond. If the maximum
number of consecutive failures is reached, and no secondary
heartbeat or remote service monitoring heartbeat is available,
the secondary unit will change its effective HA operating mode
to become the new primary unit.
For details, see “HA base port” on page 63.
Configuration Displays the time at which the secondary unit’s HA daemon
will synchronize the FortiVoice configuration from the primary
unit to the secondary unit.
The message slave unit is currently
synchronizing appears when the HA daemon is
synchronizing the configuration.
For information on items that are not synchronized, see
“Configuration settings that are not synchronized” on page 55.
Data Displays the time at which the secondary unit HA daemon will
synchronize mail data from the primary unit to the secondary
unit.
The message slave unit is currently
synchronizing appears when the HA daemon is
synchronizing data.
Actions
click HERE to
start a
configuration/
data sync
Click to manually initiate synchronization of the configuration
and call data. For information on items that are not
synchronized, see “Configuration settings that are not
synchronized” on page 55.
click HERE to
restore
configured
operating
mode
Click to reset the FortiVoice unit to an effective HA operating
mode that matches the FortiVoice unit’s configured operating
mode.
For example, for a configured primary unit whose effective HA
operating mode is now slave, after correcting the cause of the
failover, you might click this option on the primary unit to
restore the configured primary unit to active duty, and restore
the secondary unit to its slave role.
Note: Before selecting this option, if the effective HA operating
mode changed due to failover, you should resolve any issues
that caused the failover.
Table 7: Viewing HA status
GUI item Description