EasyManua.ls Logo

Fostex G16 - Page 51

Fostex G16
124 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
recording
signal
from
the
track
in
the
recording
mode
is
leaking
mto
the
track
being
reproduced.
When
sync
crosstalk
is
excessively
high,
playback
output
during
overdubbing
will
sound
muddy
by
effect
of
the
recording
signal
leakage
or
cause
oscillation
at
ping-pong
record
ing
(where
the
playback
output
is
transferred
to
another
track).
2)
Put
NR
ON/OFF
switch
to
OFF.
3)
Open
the
Controller
Panel
up,
and
take
the
Panel
Extension
out
by
unscrewing
two
screws.
4)
Prepare
the
insulated,
long
size
screw
driver
to
rotate
the
SYNC
CROSSTALK
CANCEL
LER
POTS.
5)
Rotate
the
TRACK
1
SYNC
CROSSTALK
CANCELLER
POT
(£101)
i
on
the
CONNEC-
TOR
BOARD
PCB
Assy
to
a
point
slightly
CCW
front
the
center
position?\
6)
Turn
the
RECORD
TRACK
SAFE/READY
SELECTOR
of
TRACK
1
to
SAFE
posi-
tion.
7)
Rotate
the
TRACK
2
SYNC
CROSSTALK
CANCELLER
POT
(
R102)
to
a
point
slightly
CW
from
the
full
CCW
position.
8)
Plug
in
an
audio
oscillator
output
to
the
recorder
connector
panel
INPUT
jack
2
and
apply
a
IKHz,
-
lOdBV
(0.3V)
signal.
9)
Plug
in
a
level
meter
to
the
recorder
connector
panel
OUTPUT
jack
1,
and
put
TRACK
2
in
the
REC
mode.
10)
Rotate
the
TRACK
2
SYNC
CROSSTALK
CANCELLER
POT
(R102)
CW
slowly
and
fix
it
at
a
point
3
~
5
dB
above
minimum
point
to
obtain
minimum
sync
crosstalk
in
the
high
frequency
region.
11)
Measure
the
OUTPUT
level
of
TRACK
1
while
sweeping
the
test
signal
frequency
20
~
20KHz.
It
is
considered
as
a
normal
condition
if
the
leaking
level
is
less
than
-35dBV
(18mVr.m.s.)
at
IKHz
and
less
than
-4dBV
(625mV
r.m.s.)
at
worst
peak
point
in
high
frequency
region.
12)
The
remaining
tracks
2
~
16
are
adjusted
in
the
same
way.
48