27”
39”
See
10kW 1 phase & 15kW series 3 phase: 21”
15kW series 1 phase & 30Kw series: “23”
YES Models
FES Models
23”
23”
17.5”
10Kw series: 36”
15Kw series 1 PH : 38”
15Kw series 3 PH : 36”
30Kw series: 38”
SPECIFICATIONS
ON ALL MODELS: KEEP COMBUSTIBLE MATERIALS
SUCH AS FURNITURE, PAPERS, CLOTHES AND
CURTAINS AT LEAST 3 FEET FROM THE FRONT, SIDES
AND REAR OF HEATER.
DDITIONAL CLEARANCE REQUIREMENTS FOR ALL
“YES” MODELS: THE UNIT MUST BE MOUNTED AT
LEAST 6 FEET ( OR 1.8 METERS) OFF THE FLOOR AND
2 FEET FROM THE CEILING.
REQUIRED CLEARANCES
UL File Number:
FES models..…………………………..……………E154159
YES models…………………………………………E32304
Fan Output:
10 & 15 KW series…..……………………………..800 CFM
30 KW series……………………………………....1100 CFM
Heat output:
10 KW series…………………………………….34130 BTU
15 KW series…………………………………….51120 BTU
30 KW series…………………………...………102390 BTU
Power requirements:
FES & YES 1024-1CA…………….240V, 1PH, 42 Amps
FES & YES 1520-3A………………208V, 3PH, 41.5 Amps
FES & YES 1524-1A………………240V, 1PH, 62.5 Amps
FES & YES 1524-3E………………240V, 3PH, 36 Amps
FES & YES 1548-3E………………480V, 3PH, 18 Amps
FES & YES 1560-3A………………600V, 3PH, 14.4 Amps
FES & YES 3048-3A………………480V, 3PH, 36 Amps
FES & YES 3060-3A………………600V, 3PH, 30 Am
s
IMPORTANT SAFETY INFORMATION
Read all instructions before using this heater.
SOME SMOKING MAY OC CUR DURING THE FIRST 100
MINUTES OF OPERATION. THIS IS NORMAL AND IS THE
RESULT OF A PROTECTIVE COATING ON THE HEATING
ELEMENTS. OPERATION DURING T HIS INITIAL PERIOD
SHOULD THEREFORE BE DONE IN A WELL-VENT ILATED
REA.
DO NOT USE OUTDOORS.
This heater is hot when in use. To avoid burns, do not let bare
skin touch hot surfaces. Use handle when moving this heater.
Extreme caution is necessary when any heater is used by o
near children or invali ds and whenever the heater is left
operating and unattended.
(Continued on page 2)
Issue Date: 4-19-02 Rev. Date: 12-12-03 Rev. Level: 07 OIPM P/N 3420458 Page 1 of 7