131 Milk empty
CF, CF2 only: The milk is practically used
up.
Variable: 24 V in [0.1 V] increments.
` Add milk.
132 Add cold milk cont
2
The milk is used up. All milk products are
immediately blocked.
Variable: 24 V in [0.1 V] increments.
` Add milk.
133 Milk container 2
empty
The milk is practically used up. This error
only occurs with milk systems with a milk
sensor and two milk pumps.
Variable: 24 V in [0.1 V] increments.
` Add milk
135
No text shown on the
display
The milk temperature with a Foam Master
exceeds 8°C.
This error occurs only with conductive moni-
toring and is entered into the error history a
maximum of one time per hour.
Variable: Milk temperature in °C
140 Calibrate store
The storage container with the Spectra X is
not calibrated (no gauge process carried out).
` Calibrate the flowmeter and afterwards
the storage container, see Section 6
- Programming, V.Programming, 10. Cali-
bration, 10.1 left (L), p. 126.
141 Frequency store
The level monitor of the Spectra X storage
container measures frequencies lower than
100 kHz. The sensor is missing or it is not
connected or it measures incorrectly.
` Check the sensor and replace it, if
necessary.
160 Battery low
The voltage of the battery of the CPU PCB is
less than 2.5V or not present.
Caution: All data is lost if the power supply is
interrupted while the battery is dead.
1. Back up the data
` With Service Tool 3, see Section 2 -
Commissioning, VII. Saving settings,
3. Saving settings with Service Tool,
p.32.
` With Adjust Card, see Section 6 -
Programming, VII. Programming , 11.
Data backup, p. 161.
2. Switch off the machine.
3. Replace the battery (type CR2032, 3V).
4. Switch on the machine.
5. Loading backed up data, see Section 6 -
Programming, V. Programming, 11. Data
backup, p. 161.
170 Check
water tank
The fresh water tank is empty or the waste-
water tank is full.
` Fill fresh water tank.
` Empty wastewater tank.
` Press the CLEAN button.
The error message is cleared
` If necessary, check position of the
sensors.
` Check wiring.
` Check the sensors and replace them, if
necessary.