R-410A Models
Service Manual
2 0 1 1
HG-ServMan (1-11)
SH15M30
*
SH20M30
*
Cool Only
Hazardous Duty
Room Air Conditioner
*
Last character may vary.

Questions and Answers:

Friedrich Hazardgard SH15M30 Series Specifications

General IconGeneral
BrandFriedrich
ModelHazardgard SH15M30 Series
CategoryAir Conditioner
LanguageEnglish

Summary

Safety Guidelines and Hazard Warnings

Electrical and Personal Safety

Details electrical hazards, lockout/tagout procedures, capacitor safety, and general personal protection measures.

Refrigerant and Mechanical Safety

Covers hazards associated with refrigerant handling, high pressure, and rotating mechanical components.

Hazardgard Application and Environment

Technical Specifications and Performance Data

Electrical Requirements and Wiring

Field Wiring and Circuit Protection

Details requirements for field wiring, NEC compliance, and proper circuit protection device selection.

Hazardgard Unit Features and Controls

Component Testing Procedures

Thermostat and Low Ambient Bypass Valve Operation

R-410A Refrigerant System Handling

R-410A Service Best Practices

Lists important considerations for servicing R-410A systems, including pressure, handling, and equipment requirements.

Refrigerant System Repair and Charging

Refrigerant Charge Importance

Explains the criticality of proper refrigerant charge for performance, efficiency, and compressor longevity.

Weighted Charge Method

Details the acceptable and preferred method for charging the Hazardgard system by weight.

System Under/Overcharge Diagnosis

Describes symptoms and diagnostic checks for undercharged and overcharged refrigerant systems.

Restricted System Troubleshooting

Outlines troubleshooting procedures for identifying and resolving partial and complete refrigerant restrictions.

Compressor Diagnostics and Replacement

Compressor Electrical Testing

Covers Locked Rotor Voltage (LRV), Amperage (LRA) tests, and internal overload checks for compressors.

Compressor Replacement Steps

Provides recommended procedures for replacing a compressor, including oil checks and system sealing.

Compressor Burnout System Flush

Outlines special procedures for cleaning the system after a compressor burnout, including flushing and acid neutralization.

Routine Maintenance Procedures

Performance Testing and Unit Sizing

Troubleshooting Common Issues

Unit Operation and Thermostat Faults

Addresses issues like unit not running, continuous compressor operation, evaporator freezing, and thermostat problems.

Compressor Start and Cooling Performance Issues

Solves compressor start failures, intermittent operation, poor cooling, and icing conditions.

Control System Wiring and Schematics