Sidefillerpanelsarenecessaryto
isolatetheunitfromadjoining
cabinets.
To reduce the risk of
personal injury and
tipping the wall
oven, the wall oven
must be secured to
the cabinet(s) by
properly installed
anti=tip screws or
brackets.
36" Min.
(91.4 cm)
Jse 3/4" (1.9 cm) plywood, installed
on two runners, flush with toe plate.
Must be capable of supporting 150
pounds. (68 kg).
Cut an opening in wood base
minimum 9*' x 9" (23 x 23 cm), 2"
(5 cm) from left side filler panel, to
route armored cable to the wall
outlet or junction box.
_'i__ii!i!I!I_!I_III!I!I!I_!I_III!I!I!I_!I_III!I!I!I_!I_III!I!I!I_!I_III!I!I!I_!I_III!I!I!I_!I_III!I!I!I_!I_III!I!I!I_!I_III!I!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!__
30" (762cm) 28 1/2 _ (724cm) Min 28 1/4 _ (718cm) Min
Wall Oven 29" (737 cm) Max 24" (61 cm) Min 28 7/8" (733 cm) Max
Figure 10 - TYPICAL UNDER COUNTER INSTALLATION OF AN ELECTRIC BUILT-IN OVEN
30" SINGLE WALL OVEN ONLY
7