11
INSTALLING THE HOSE CONNECTOR
1. To continuously fill the water tank with water using a garden hose, screw
the larger end of the supplied hose connector to the continuous water inlet.
Ensure the connector is securely connected.
2. Fully insert the small PVC pipe all the way into the narrow end of the hose
connector. There should be approximately 0.5” of the PVC pipe extending
out of the hose connector. Attach a garden hose to the PVC pipe and clamp
the two together using the metal clamp.
ADJUSTING THE AIR LOUVERS
1. To adjust the air louvers, turn the SWING dial to the ON position. The air
louvers will automatically move horizontally, improving the distribution of
cooled air throughout your space.
2. To turn off the automatic swinging function, turn the SWING dial to the
OFF position.
3. You can also adjust the vertical direction of the air louvers by manually
adjusting them.