Entering Diagnostic Mode
Full Control Reset
1. Wake up unit.
2.
Place cycle selector knob in 12:00 O’Clock
position.
12:00 o’cloc
3. Position temp knob all the way to the left.
temp
4.
Press and hold START button for 10 seconds.
You will hear one short beep to indicate you
completed Full Control Reset. Release START
button.
5.
Place cycle selector knob in 11:00 O’Clock
position.
Within 15 seconds, complete all of the follow-
ing instructions to enter Diagnostic Mode.
11:00 o’cloc
Entering Diagnostic Mode
1.
Turn temp knob all the way to the left.
Press and release START button.
temp
2.
Turn temp knob all the way to the right.
Press and release START button.
temp
3.
Turn temp knob all the way to the left.
Press and release START button.
You will hear one long beep to indicate you
are in Diagnostic Mode.
temp
NOTE
If left unattended in Diagnostic Mode for more than
5 minutes, the unit will automatically exit Diagnostic
Mode and return to normal functionality.
Exiting Diagnostics
1.
Press and hold CANCEL button for 5 sec-
onds.
You will hear one short beep to indicate you
have exited Diagnostic mode.
ENGLISH
Diagnostic Sub-Routine Selection
After entering Diagnostic Mode, select a Diagnostic Sub-Routine.
See Sub-Routine sections on next page.
alarm mode
test mode
factory test mode
(not for use in eld)
factory test mode
(not for use in eld)
Possible User Executions While in Diagnostic Mode
Press and hold CANCEL to exit Diagnostic Mode and
return to normal operation. Chime will sound one short
beep as you exit Diagnostic Mode.
Rotate cycle selector to desired Sub-Routine:
Alarm Mode or Test Mode.
Press START to enter selected Sub-Routine. See next
page.