FROMM
CH12-TI-FS250.EN10
THE MACHINE DOES NOT STOP WHEN THE EMERGENCY MUSHROOM-HEAD BUTTON IS
PRESSED
The arrised problem
Possible remidies
- emergency circuit failure - Check the circuit
- emergency mushroom-head button not working
- Replace the emergency mushroom-
head button
THE TURNS AT THE BOTTOM AND AT THE TOP OF THE LOAD ARE NOT REGULATED
PROPERLY
The arrised problem
Possible remidies
- limit switches (1) not connected properly - Check the wiring
- limit switch malfunctioning - Replace the limit switch
-The control card (2) is not working properly
- Replace the faulty card by carefully
referring to the wiring diagram attached to
the machine documentation
ALARMS AND ERRORS
1
2