26
During the analysis phase, the charger mo-
nitors the battery voltage and the result is
used in the subsequent charging process.
- A set of four bars shows the state of
charge of the battery (e.g. the third bar
represents a state of charge of 80%).
- All four bars are continuously display-
ed.
- The state of charge is 100%.
- The battery is ready to use.
- The battery may remain connected to
the charger for any length of time.
- Conservation charging counteracts
battery self-discharge.
Disconnect the charger
- Disconnect the black charger lead from the negative pole (-) on the battery
- Disconnect the red charger lead from the positive pole (+) on the battery
Interrupting re-
fresh charging
Resuming refresh
charging
CAUTION! Risk of sparks if the charger leads are disconnected too soon. Before
disconnecting the charger leads, press the Stop/Start key to finish charging.
To terminate Refresh charging:
- Press the Stop/Start key
NOTE! Danger of damage to connection sockets and plugs. Do not disconnect or
unplug charger leads while reactivating.
Press the Stop/Start key while reactivating
- Refresh charging is interrupted
1
Press the Stop/Start key
- Refresh charging is resumed
1