Charging errors
No. 30: Timeout in the corresponding
charging phase
Remedy:
- Set Ah to correct value
- Check for parallel consumers (car ra-
dio, etc.)
- Battery temperature too high
No. 31: Too many Ah charged, too few Ah set
Remedy:
- Set Ah to correct value
- Check for parallel consumers (car radio, etc.)
- Replace battery if it appears to be faulty
No. 32: Optional external temperature sensor has tripped due to undertemperature
Remedy:
- Charge the battery in a more suitable area
No. 33: Optional external temperature sensor has tripped due to overtemperature
Remedy:
- Allow battery to cool, or charge battery in a more suitable area
No. 34: Battery voltage set too high
Remedy:
- Set the correct battery voltage
No. 35: Voltage below target voltage after 2 h - Refresh mode in analysis phase
Remedy:
- Check for parallel consumers (car radio, etc.)
- Replace battery if it appears to be faulty
No. 36: Cell short circuit
Remedy:
- Check for parallel consumers (car radio, etc.)
- Replace battery if it appears to be faulty
No. 37: Conservation charge current too high
Remedy:
- Check for parallel consumers (car radio, etc.)