Technical data
Electrical data in-
put
Electrical data
output
Battery data
Technical data
Environmental
conditions
Standards
Mains voltage ~ 230 V AC, +/- 15 %
Mains frequency 50 / 60 Hz
Mains current max. 9 A eff.
Mains fuse protection max. 16 A
Efficiency max. 96 %
Effective power max. 1120 W
Power consumption (standby) max. 2.4 W
Protection class I (with PE conductor)
Maximum permitted mains impedance at the inter-
face (PCC) to the public grid
None
EMC emission class A
Marks of conformity CE
Nominal output voltage 6 V / 12 V / 24 V DC
Output voltage range 2 V - 33.6 V
Output current 35 A at 28.8 V DC
35 A at 14.4 V DC
35 A at 7.2 V DC
Battery return current < 1 mA
6 V / 12 V / 24 V DC 3 - 350 Ah
Cooling Convection and fan
Dimensions l x w x h 270 x 168 x 100 mm
Weight (without cable) 2 kg
Operating temperature -20 °C - +40 °C (>30 °C derating)
Storage temperature -40 °C - +85 °C
Climate class B
Degree of protection IP40
IEC 60068-2-6 Sine oscillations (10 - 150 Hz; 1.5 h
/ axis)
IEC 60068-2-29 Repetitive shock (25 g / 6 ms /
1000 shocks)