Attaching the
mounting brack-
et to a metal car-
rier
NOTE!
When mounted on metal supports, the inverter must not be exposed to rainwa-
ter or splashing water from the rear.
Provide suitable rainwater protection or splash water protection.
The mounting bracket must be secured in at least four places.
1
Installing the in-
verter on a mast
Example of a mast mounting kit
For installation of the inverter on a
mast or beam, Fronius recommends
using the "Pole clamp" (order no.
SZ 2584.000) mast mounting kit from
Rittal GmbH.
With the kit, the inverter can be moun-
ted on a round or rectangular mast
with the following diameter: Æ from 40
to 190 mm (round mast)
ÿ from 50 to 150 mm (rectangular
mast)