Thermal concept Ambient air is drawn in at the front of
the device by the fan and blown out at
the sides. The even heat dissipation al-
lows several inverters to be installed
next to each other.
NOTE!
Risk due to insufficient cooling of the inverter.
This may result in a loss of power in the inverter.
▶
Do not block the fan (e.g., with objects that protrude through the touch
guard).
▶
Do not cover the ventilation slots, even partially.
▶
Make sure that the ambient air can always flow through the inverter's ventila-
tion slots unimpeded.
Data backup The user is responsible for backing up any changes made to the factory settings.
The manufacturer accepts no liability for any deleted personal settings.
Fronius Sol-
ar.web
System owners and installers can easily monitor and analyze the PV system using
Fronius Solar.web or Fronius Solar.web Premium. With the appropriate configur-
ation, the inverter transmits data such as power, yield, load, and energy balance
to Fronius Solar.web. More detailed information can be found at Solar.web - Mon-
itoring & analysis.
Configuration is carried out using the Setup wizard; see the chapter headed In-
stallation with the app on page 68 or Installation with the browser on page
68.
Requirements for configuration:
-
Internet connection (download: min. 512 kbit/s, upload: min. 256 kbit/s)*.
-
User account at solarweb.com.
-
Completed configuration using the Setup wizard.
* These specifications do not provide an absolute guarantee of flawless op-
eration. High error rates in the transmission, fluctuating receptions or mis-
fires can have an adverse effect on data transfer. Fronius recommends on-
site testing to ensure that the connections meet the minimum require-
ments.
15