Fronius Primo GEN24 4.6 / 4.6 Plus 5.0 / 5.0 Plus 6.0 / 6.0 Plus
Nominal output power (per phase)
7)
3680 W
Nominal output current (per phase) 16 A
Nominal grid voltage
3 ~ NPE 220 V / 380 V
3 ~ NPE 230 V / 400 V
Nominal frequency for Full Backup
53 / 63 Hz
1)
Switchover time < 90 s
Power factor cos phi
2)
0 - 1
General data
Maximum efficiency 97.6% 97.6% 97.6%
European efficiency (U
mpp nom
)
97.2% 97.2% 97.1%
European efficiency (U
mpp max
)
96.6% 96.7% 96.7%
European efficiency (U
mpp min
)
96.2% 96.3% 96.1%
Self-consumption at night
6.8 W
Cooling Controlled forced-air ventilation
Degree of protection IP 66
Dimensions H x W x D 528 × 474 × 163 mm
Weight 15.4 kg
Permissible ambient temperature -40 °C – +60 °C
Permissible humidity 0–100% (incl. condensation)
EMC device class B
DC / AC overvoltage category 2 / 3
Pollution degree
2
Sound pressure
42 dB(A) (ref. 20µPa)
Safety class (according to IEC62103) 1
Protection devices
DC insulation measurement Warning / shutdown at R
ISO
< 600 kOHM
Manifestation of DC overload Operating point shift, power limiter
DC disconnector Integrated
RCMU Integrated
Data communication
WLAN SMA-RP connection
(FCC ID: QKWPILOT01 / IC ID: 12270A-PILOT01)
802.11b/g/n (WPA, WPA2)
Ethernet (LAN) RJ45, 10/100 MBit
USB (type A socket) max. 1 A at 5 V (IO connection not connected)
Wired shutdown (WSD)
max. 28 devices/WSD chain
max. distance between two devices = 100 m
Modbus RTU SunSpec (2x) RS485 2-wire
141
EN