9
Insert the DC terminals into the re-
spective slot until they engage. Fasten
the screws of the cable guide to the
housing using a screwdriver (TX20) and
a torque of 1.3-1.5 Nm.
NOTE!
Do not use a drill driver as this could
cause overturning.
A possible consequence of overturning
is, for example, damaging the strain-re-
lief device.