23
Appropriate Grids
Delta
Setup:
208
240
220
BR
50HZ
MG 3P
MG 1P
No neutral conductor
Nominal voltage:
208 V
240 V
220 V
220 V
50 Hz 208 - 240 V
Microgrid 208 V
Microgrid 240 V
Appropriate Inverters:
Symo 10.0-3 208-240 /
12.0-3 208-240 / 15.0-3 208
WYE
Setup:
208N
220N
BR N
50HN
HI2
480N
440N
50HN
MG 3N
MG 2N
MG 5N
MG 6
CAL3
HI3
Neutral conductor necessary
Nominal voltage:
208 V
220 V
220 V
50 Hz 208 - 240 V
208 V
480 V
440 V
50 Hz 415 V
Microgrid 208 V
Microgrid 50 Hz 208 - 240 V
Microgrid 50 Hz 480 V
Microgrid 480 V
480 V
480 V
Appropriate Inverters:
Symo 10.0-3 208-240 /
12.0-3 208-240 / 15.0-3 208
Symo 10.0-3 480 / 12.5-3
480 / 15.0-3 480 / 17.5-3
480 / 20.0-3 480 / 22.7-3
480 / 24.0-3 480
Stinger
Setup:
240N
50HN
MG 1N
MG 2N
HI1
Neutral conductor necessary
Nominal voltage:
240 V
50 Hz 208 - 240 V
Microgrid 240 V
Microgrid 50 Hz 208 - 240 V
208 V
Appropriate Inverters:
Symo 10.0-3 208-240 /
12.0-3 208-240
=
~
L1
L2
L3
L2-L3
120°
=
~
L1
L2
L3
N
L2-L3
120°
=
~
L3
L1
L2
N
L1-NL2-N
120°
L2-L3
L3-L1