Carefully open the Minitek plug (2)
lock
4
Remove the socket housing (3) by
pushing forwards
(2)
ABCDEF
Pink
Grey
Yellow
White
Brown
Green
-i
(4)
(3)
(5)
(2)
U/D
NOTE!
Observe the pin assignment
*
(color-
coded arrangement of the wires) for
each interface version and note it down
in advance.
5
Release the wires (4) using tweezers
and pull them out
6
Replace the socket housing (3)
7
Insert the wires (4) into the socket
housing (3) according to the color-
coded arrangement
*
per interface ver-
sion and check the lock
8
Push the socket housing (3) into the
Minitek plug (2) and lock it (5)
(2)
(1)
(6)(7)
9
Position the Minitek plug (2) in the
handle
NOTE!
Observe the following when positioning
the Minitek plug:
Press the cable sheathing (6) right
down to the bottom of the strain-relief
device guide
Lay the control line (7) in a loop
underneath the handle screw connec-
tion
10
Insert the coupling housing (1) and
close the hand grip as per the “Closing
the hand grip” chapter