(2)(1)
NOTE!
The coupling housing must be replaced
as a closed unit.
3
Remove the contact element (1)
4
Carefully remove the coupling housing
(2)
(2)(1)
Installation
1
Fit the coupling housing (2)
2
Insert the contact element (1)
(1)
3
Pre-mount the contact element (1)
with 8 mm socket
4
Secure the contact element (1) with a
torque screwdriver and socket as per
the “Required tools” chapter
Tightening torque: 5 Nm
5
Close the hand grip as per the “Clos-
ing the hand grip” chapter