Replacing the
coupling housing
(1)
Removal
1
Open the hand grip as per the “Open-
ing the hand grip” chapter
NOTE!
Carefully place the socket onto the con-
tact element to prevent damage.
2
Open the contact element (1) with the
8 mm socket
(1) (2)
NOTE!
The coupling housing must be replaced
as a closed unit.
3
Remove the contact element (1)
4
Carefully remove the coupling housing
(2)
(1) (2)
Installation
1
Fit the coupling housing (2)
2
Insert the contact element (1)