d-type manual torch:
1
Connect the test box manual torch (1)
directly to the d-manual torch’s control
line (2), as shown
2
Make settings on the test box:
- Up/Down = TIG-torches
3
Check the operating elements are
working correctly for each interface
version
Example: Electrical test Up/Down as per PP-3208 test schedule:
a) Rocker switch left long, press forwards = LED final current
b) Rocker switch left long, press backwards = LED main current
c) Rocker switch right short, press forwards = LED down
d) Rocker switch right short, press backwards = LED up
SH-type manual torch - Up/Down:
1
Connect the test box manual torch (1)
to the manual torch’s control line (3)
via the adapter cable (2), as shown
2
Make settings on the test box:
- Up/Down = TIG-torches
3
Check the operating elements are
working correctly for each interface
version
Example: Electrical test Up/Down:
a) Rocker switch left long, press forwards = LED final current
b) Rocker switch left long, press backwards = LED main current
c) Rocker switch right short, press forwards = LED down
d) Rocker switch right short, press backwards = LED up