82
Set-up parame-
ters for MMA
welding
IMPORTANT! If you reset the power source using the FAC factory set-up parameter, the
hot-current time (Hti) and HotStart current (HCU) set-up parameters are also reset.
HCU
HotStart current
Unit: %
Setting range: 100 - 200
Factory setting: 150
Hti
Hot-current time
Unit: s
Setting range: 0 - 2.0
Factory setting: 0.5
Ast
Anti-stick
Unit: -
Setting range: On, Off
Factory setting: Off
FAC
Reset power source to factory setting
Press and hold down one of the "Parameter selection" buttons for 2 s to restore the
factory settings
- when "PrG" appears on the digital display, the power source has been reset.
IMPORTANT! When the power source is reset, all personal settings are lost.
When the power source is reset, operating points that were saved using the "Save"
buttons are not deleted, but are retained in the memory. The functions in the sec-
ond level of the set-up menu (2nd) are also not deleted. Exception: Ignition time-
out (ito) parameter.
2nd
second level of the set-up menu (see "Set-up menu - Level 2")