102
Parameters for MMA welding
Parameters for
MMA welding
SEt Country-specific setting (Standard/USA) Std/US
Unit: -
Setting range: Std, US (Standard/USA)
If Std is selected, the EURO welding programs are used as stated in the welding
program table.
If US is selected, the US welding programs are used as stated in the welding pro-
gram table.
Factory setting:
Standard version: Std (measurements: cm/mm)
USA version: US (measurements: inches)
r Welding circuit resistance (in mOhm)
See section "Measuring welding circuit resistance r"
L Welding circuit inductivity (in microhenrys)
See section "Displaying welding circuit inductivity L"
FUS Mains fuse protection
The maximum possible welding power is limited by the rating of the mains fuse
protection.
Unit: A
The available mains fuse ratings are determined by the SEt parameter setting:
SEt parameter set as Std: OFF / 10 / 13 / 16
SEt parameter set as US: OFF / 15 / 20 (only for 120 V mains voltage)
Factory setting: OFF