Troubleshooting
Safety
Fault diagnosis Make a note of the serial number and configuration of the device and contact our After-
Sales Service team with a detailed description of the error, if
- errors occur that are not listed below
- the troubleshooting measures listed are unsuccessful
Power source has no function
Mains switch is on, but indicators are not lit up
Cause: There is a break in the mains lead; the mains plug is not plugged in
Remedy: Check the mains lead, ensure that the mains plug is plugged in
Cause: Mains socket or mains plug faulty
Remedy: Replace faulty parts
Cause: Mains fuse protection
Remedy: Change the mains fuse protection
Nothing happens when the torch trigger is pressed
Power source mains switch is ON and indicators are lit up
Cause: Welding torch or welding torch control line is faulty
Remedy: Replace the welding torch
WARNING! Work that is carried out incorrectly can cause serious injury and dam-
age. All the work described below must only be carried out by trained and quali-
fied personnel. Do not carry out any of the work described below until you have
fully read and understood the following documents:
- This document
- all the operating instructions for the system components, especially the safe-
ty rules
WARNING! An electric shock can be fatal. Before starting the work described be-
low:
- Turn the power source mains switch to the "O" position
- Disconnect the power source from the mains
- Ensure that the power source remains disconnected from the mains until all
work has been completed
After opening the device, use a suitable measuring instrument to check that elec-
trically charged components (e.g. capacitors) have been discharged.
WARNING! An inadequate ground conductor connection can cause serious inju-
ry or damage. The housing screws provide a suitable ground conductor connec-
tion for grounding the housing and must NOT be replaced by any other screws
that do not provide a reliable ground conductor connection.