116
to1 | xxx
Note: xxx stands for a temperature value
Cause: Overtemperature on the booster located in the power source
Remedy: Allow power source to cool down, check air filter and clean if necessary,
check that fan is on
to2 | xxx
Note: xxx stands for a temperature value
Cause: Overtemperature in the secondary circuit of the power source
Remedy: Allow power source to cool down, check air filter and clean if necessary,
check that fan is on
to3 | xxx
Note: xxx stands for a temperature value
Cause: Overtemperature in wirefeeder motor
Remedy: Allow wirefeeder to cool down
to4 | xxx
Note: xxx stands for a temperature value
Cause: Overtemperature in welding torch
Remedy: Allow welding torch to cool down
to6 | xxx
Note: xxx stands for a temperature value
Cause: Overtemperature on the power source transformer
Remedy: Allow power source to cool down, check air filter and clean if necessary,
check that fan is on
to7 | xxx
Note: xxx stands for a temperature value
Cause: Overtemperature in the power source
Remedy: Allow power source to cool down, check air filter and clean if necessary,
check that fan is on
toF | xxx
Cause: The power source's safety cut-out reacted in order to prevent tripping of the
mains fuse.
Remedy: After a pause in welding of around 60 s, the message disappears and the
power source is operational again.
tu0 | xxx
Note: xxx stands for a temperature value
Cause: Undertemperature in the power source primary circuit
Remedy: Place power source in a heated room and allow it to warm up