EasyManua.ls Logo

Fronius TransSteel 2200c - Care, Maintenance, and Disposal

Fronius TransSteel 2200c
128 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
118
Care, maintenance and disposal
General Under normal operating conditions, the welding system requires only a minimum of care
and maintenance. However, it is vital to observe some important points to ensure the weld-
ing system remains in a usable condition for many years.
Safety
At every start-up - Ensure that the mains plug and mains cable as well as the welding torch / electrode
holder are undamaged. Replace any damaged components
- Ensure that a proper ground earth connection has been established to the workpiece
- Check that there is an all-round clearance of 0.5 m (1 ft. 8 in.) around the device to
ensure that cooling air can flow in and out freely
WARNING! Work that is carried out incorrectly can cause serious injury and dam-
age. All the work described below must only be carried out by trained and quali-
fied personnel. Do not carry out any of the work described below until you have
fully read and understood the following documents:
- This document
- all the operating instructions for the system components, especially the safe-
ty rules
WARNING! An electric shock can be fatal. Before starting the work described be-
low:
- Turn the power source mains switch to the "O" position
- Disconnect the power source from the mains
- Ensure that the power source remains disconnected from the mains until all
work has been completed
After opening the device, use a suitable measuring instrument to check that elec-
trically charged components (e.g. capacitors) have been discharged.
WARNING! An inadequate ground conductor connection can cause serious inju-
ry or damage. The housing screws provide a suitable ground conductor connec-
tion for grounding the housing and must NOT be replaced by any other screws
that do not provide a reliable ground conductor connection.
NOTE! Air inlets and outlets must never be covered, not even partially.

Table of Contents