126
TSt 2200c MV
Mains voltage (U
1
) 1 x 120 V
Max. effective primary current (I
1eff
) 15 A
Max. primary current (I
1max
) 20 A
Mains fuse protection 15 A slow-blow
Mains voltage (U
1
) 1 x 120 V
Max. effective primary current (I
1eff
) 20 A
Max. primary current (I
1max
) 29 A
Mains fuse protection 20 A slow-blow
Mains voltage (U
1
) 1 x 230 V
Max. effective primary current (I
1eff
) 16 A
Max. primary current (I
1max
) 26 A
Mains fuse protection 16 A slow-blow
Mains voltage (U
1
) 1 x 240 V
Max. effective primary current (I
1eff
) 15 A
Max. primary current (I
1max
) 26 A
Mains fuse protection 15 A slow-blow
Mains voltage tolerance -20 / +15%
Mains frequency 50/60 Hz
Cos phi (1) 0.99
Max. permissible mains impedance Z
max
on PCC
1)
250.02 mOhm
Recommended earth-leakage circuit breaker Type B
Welding current range (I
2
)
MIG/MAG 10 - 210 A
Rod electrode 10 -180 A
TIG 10 - 230 A
Welding current at 10 min/40 °C (104 °F) 30 % 60 % 100%
MIG/MAG U
1
120 V (15 A) 105 A 95 A 80 A
U
1
120 V (20 A) 135 A 120 A 105 A
U
1
230 V 210 A 170 A 150 A
Welding current at 10 min/40 °C (104 °F) 35 % 60 % 100%
Rod electrode U
1
120 V (15 A) 90 A 80 A 70 A
U
1
120 V (20 A) 110 A 100 A 90 A
U
1
230 V 180 A 150 A 130 A
Welding current at 10 min/40 °C (104 °F) 35 % 60 % 100%
TIG U
1
120 V (15 A) 135 A 120 A 105 A
U
1
120 V (20 A) 160 A 150 A 130 A
U
1
230 V 230 A 200 A 170 A
Output voltage range according to standard characteristic (U
2
)
MIG/MAG 14.5 – 24.5 V