67
EN
MIG/MAG standard synergic welding
MIG/MAG stand-
ard synergic
welding
Press the "Process" button to select SYNERGIC
Press the "Mode" button to select the desired MIG/MAG mode:
2-step mode
4-step mode
S 4 T - Special 4-step mode
Spot welding/stitch welding
Press the "Material" button to select the filler metal to be used
Press the "Wire diameter" button to select the diameter of the wire electrode used
Press the "Shielding gas" button to select the shielding gas used
Use the "Parameter selection" buttons to select and set the welding parameters to be
used to specify the welding power:
Sheet thickness
Welding current
Wire speed
Welding voltage
All parameter set values remain stored until the next time they are changed. This applies
even if the power source is switched off and on again.
Ensure that the grounding (earthing) connection has been established
Ensure that the shielding gas supply has been established
- Power source is ready for welding
Corrections dur-
ing welding
The arc length correction and arc-force dynamic parameters can be used to optimise the
welding result.
NOTE! Under certain circumstances, it may not be possible to change weld-
ing parameters that have been set for a system component (remote control,
etc.) on the control panel of the power source.
1
2
3
4
5
6
8
9
Arc-force dynamic:
For influencing the short-circuiting dynamic at the moment of droplet transfer
- = hard, stable arc
0 = neutral arc
+ = soft, low-spatter arc
Arc length correction:
- = shorter arc, reduced welding voltage
0 = neutral arc
+ = longer arc, increased welding voltage