93
EN
SPt Spot welding time
Unit: Seconds
Setting range: 0.3 - 5
Factory setting: 1
SPb Spot pause time
Unit: Seconds
Setting range: OFF, 0.3 - 10 (in 0.1 s increments)
Factory setting: OFF
Int Interval
Unit: -
Setting range: 2T (2-step), 4T (4-step)
Factory setting: 2T (2-step)
FAC Reset power source to factory settings
Press and hold one of the "Parameter selection" buttons for two seconds to restore
the factory settings
- when "PrG" appears on the digital display, the power source has been reset.
2nd Second level of the Setup menu (see "Setup menu - level 2")
NOTE! The ignition time-out function (Ito) is a safety feature – if the power
source determines that no ignition has occurred after the preset wire length
has been fed, wirefeeding is stopped.
NOTE! If the power source is reset, the majority of the applied settings are
deleted. The following values remain:
- Welding circuit resistance and welding circuit inductivity
- Country-specific setting