Setup parameters
for MIG/MAG
standard manual
welding
"Min." and "max." are used for setting ranges that differ according to power source, welding
program, etc.
GPr Gas pre-flow time
Unit: s
Setting range: 0 - 9.9
Factory setting: 0.1
GPo Gas post-flow time
Unit: s
Setting range: 0 - 9.9
Factory setting: 0.5
Fdi Feeder inching speed
Unit: m/min (ipm)
Setting range: 1 - max. (39.37 - max.)
Factory setting: 10 (393.7)
SL Slope (special 4-step mode only)
Unit: s
Setting range: 0 - 9.9
Factory setting: 0.1
I-S I (current) - Starting - Starting current (special 4-step mode only)
Unit: % (of welding current)
Setting range: 0 - 200
Factory setting: 100
I-E I (current) - End: Final current (special 4-step mode only)
Unit: % (of welding current)
Setting range: 0 - 200
Factory setting: 50
t-S t (time) - Starting - Starting current duration (special 4-step mode only)
Unit: s
Setting range: OFF, 0.1 - 9.9
Factory setting: OFF
t-S t (time) - End: Final current duration (special 4-step mode only)
Unit: s
Setting range: OFF, 0.1 - 9.9
Factory setting: OFF
bbc burn-back time correction
Wire burn-back effect due to wire withdrawal at end of welding
Unit: -
Setting range: 0 - 20
Factory setting: 0
IGC Ignition current
Unit: A
Setting range: 100 - 650
Factory setting: 500
Ito Ignition time-out - length of wire that is fed before the safety cut-out is trig-
gered
Unit: mm (in.)