EasyManua.ls Logo

Fronius TransSteel 3500 - General Troubleshooting Guidance

Fronius TransSteel 3500
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
49
EN
Troubleshooting
General The power sources are equipped with an intelligent safety system. This means that it has
been possible to dispense with melting-type fuses entirely. Melting-type fuses therefore no
longer need to be replaced. After a possible malfunction has been remedied, the power
source is ready for use again.
Safety
WARNING!
Work that is carried out incorrectly may result in serious injury or damage to prop-
erty.
The activities described below must only be carried out by trained and qualified per-
sonnel.
Observe the safety rules in the power source Operating Instructions.
WARNING!
An electric shock can be fatal.
Before opening the unit
Turn the mains switch to the "O" position
Unplug the device from the mains
Put up an easy-to-understand warning sign to stop anybody inadvertently switching it
back on again
Using a suitable measuring device, check to make sure that electrically charged com-
ponents (e.g. capacitors) have discharged
WARNING!
An inadequate ground conductor connection can cause serious injury or damage.
The housing screws provide a suitable ground conductor connection for earthing the hous-
ing.
The housing screws must NOT be replaced by any other screws that do not provide a
reliable ground conductor connection.
Power source -
troubleshooting
Make a note of the serial number and configuration of the device and contact our After-
Sales Service team with a detailed description of the error, if
- errors occur that are not listed below
- the troubleshooting measures listed are unsuccessful
Over-temperature LED lights up
Cause: Over-temperature in control circuit
Remedy: Leave power source to cool