EasyManua.ls Logo

Fronius TransSteel 5000 Syn - Retrieving the Welding Circuit Inductivity L; General; Displaying Welding Circuit Inductivity; Laying the Hosepacks Correctly

Fronius TransSteel 5000 Syn
144 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Retrieving the welding circuit inductivity L
General Laying of the hosepacks has a significant effect on welding circuit inductivity and
therefore affects the welding process. It is important to lay the hosepacks cor-
rectly in order to obtain the best possible welding result.
Displaying weld-
ing circuit in-
ductivity
The setup parameter "L" is used to display the most recently calculated welding
circuit inductivity. The welding circuit inductivity is calibrated at the same time as
the welding circuit resistance is measured. Detailed information can be found in
the "Measuring welding circuit resistance" section.
1
Access the Level 2 (2nd) Setup menu
2
Select parameter "L"
The most recently calculated welding circuit inductivity L is shown on the right-
hand digital display.
L ... Welding circuit inductivity (in microhenry)
Laying the
hosepacks cor-
rectly
104

Table of Contents

Other manuals for Fronius TransSteel 5000 Syn

Related product manuals