TSt 5000 MV
Syn
Mains voltage (U
1
) 3 x 200 V 230 V
Max. effective primary current (I
1eff
) 39.5 A 36.3 A
Max. primary current (I
1max
) 66.7 A 57.4 A
Mains fuse protection 63 A slow-blow
Mains voltage (U
1
) 3 x 400 V 460 V
Max. effective primary current (I
1eff
) 20.6 A 18.1 A
Max. primary current (I
1max
) 32.5 A 28.6 A
Mains fuse protection 35 A slow-blow
Mains voltage tolerance -10 / +15%
Grid frequency 50 / 60 Hz
Cos phi (1) 0.99
Max. permissible mains impedance Z
max
on PCC
1)
63 mOhm
Recommended earth-leakage circuit break-
er
Type B
Welding current range (I
2
) MIG / MAG 10 - 500 A
Rod electrode 10 - 500 A
Welding current at 10 min / 40 °C (104
°F)
35% 60% 100%
U
1
: 200 V 500 A 420 A 360 A
Welding current at 10 min / 40 °C (104
°F)
40% 60% 100%
U
1
: 208 - 460 V 500 A 420 A 360 A
Output voltage range according
to standard characteristic (U
2
)
MIG / MAG 14.3 - 39 V
Rod electrode 20.2 - 40 V
Open circuit voltage (U
0
peak / U
0
r.m.s) 57 V
Apparent power
at 200 V AC / 500 A / 40 % ED
2)
23,08 kVA
at 400 V AC / 500 A / 40 % ED
2)
22,49 kVA
Degree of protection IP 23
Type of cooling AF
Insulation class B
Overvoltage category III
Pollution level according to IEC60664 3
Safety symbols S, CE, CSA
Dimensions l x w x h 747 x 300 x 497 mm
29.4 x 11.8 x 19.6 in.
Weight 43.6 kg / 96.1 lb.
Max. noise emission (L
WA
) 75 dB (A)
Idle state power consumption at 400 V 82,7 W
Power source efficiency at 500 A / 40 V 90 %
126