Connecting the mains cable
Safety
WARNING!
Danger due to work that has been carried out incorrectly.
This can result in serious injury and damage to property.
The work described below must only be carried out by trained and qualified
personnel.
Observe national standards and directives.
CAUTION!
Danger due to improperly prepared mains cable.
This can cause short circuits and damage.
Fit ferrules to all phase conductors and the ground conductor of the
stripped mains cable.
General If no mains cable is connected, a mains cable that is suitable for the connection
voltage must be fitted before commissioning.
A strain-relief device for the following cable cross-sections is fitted to the power
source:
Power source Cable cross-section
fitted strain-relief device
for
Canada / US
Europe
TSt 3500 Syn AWG 12 *) 4G2.5
TSt 5000 Syn AWG 10 *) 4G4
TSt 3500 MV Syn AWG 10 *) 4G4
TSt 5000 MV Syn AWG 6 *) 4G10
*) Canada / US cable type: Extra-hard usage
Strain-relief devices for other cable cross-sections must be designed accord-
ingly.
Stipulated mains
cables and
strain-relief
devices
Power source Mains voltage Cable cross-sec-
tion
Canada / US
Europe
TSt 3500 Syn 3 x 380 / 400 V AWG 12 *) 4G2.5
3 x 460 V AWG 12 *) 4G2.5
TSt 5000 Syn 3 x 380 / 400 V AWG 8 *) 4G4
3 x 460 V AWG 10 *) 4G4
TSt 3500 MV
Syn
3 x 208 / 230 / 400 / 460
V
AWG 10 *) 4G4
44